WeatherForecastCSC

class lsst.ts.weatherforecast.WeatherForecastCSC(initial_state=State.STANDBY, simulation_mode=0, config_dir=None, override='')

Bases: ConfigurableCsc

Implement the WeatherForecast CSC.

The WeatherForecast Commandable SAL Component simply streams forecast information from the Meteoblue API service. It uses an API Key to authenticate with the web service. It then publishes the data to the EFD via SAL telemetry.

Parameters
initial_statesalobj.State

The initial state that the CSC starts in.

simulation_modeint

Whether the CSC is in simulation mode.

  • 0 - real mode

  • 1 - simulated data

  • 2 - simulated missing data

Notes

Simulation mode has three values.

  • 0 - real data mode.

  • 1 - Simulated data mode.

  • 2 - Missing data mode.

Attributes
telemetry_taskasyncio.Future

A task that handles the telemetry loop.

last_timeNone

The last time that the forecast was updated. (UTC)

intervalint

The interval at which the telemetry loop is run. (Seconds)

mock_serverNone

The mock server started if simulation_mode is enabled.

tel_loop_error_wait_time: `int`

The wait time for retrying if the API call fails.

api_keystr

The stored API key for Meteoblue received from an environment variable.

Attributes Summary

config_dir

Get or set the configuration directory.

default_initial_state

disabled_or_enabled

Return True if the summary state is State.DISABLED or State.ENABLED.

domain

enable_cmdline_state

simulation_help

simulation_mode

Get the current simulation mode.

summary_state

Get the summary state as a State enum.

valid_simulation_modes

version

Methods Summary

add_arguments(parser)

Add arguments to the parser created by make_from_cmd_line.

add_kwargs_from_args(args, kwargs)

Add constructor keyword arguments based on parsed arguments.

amain(index, **kwargs)

Make a CSC from command-line arguments and run it.

assert_enabled([action])

Assert that an action that requires ENABLED state can be run.

begin_disable(data)

Begin do_disable; called before state changes.

begin_enable(data)

Begin do_enable; called before state changes.

begin_exitControl(data)

Begin do_exitControl; called before state changes.

begin_standby(data)

Begin do_standby; called before the state changes.

begin_start(data)

Begin do_start; configure the CSC before changing state.

check_for_duplicate_heartbeat([num_messages])

Monitor heartbeat events and return True if any have a different private_origin.

close([exception, cancel_start])

Shut down, clean up resources and set done_task done.

close_tasks()

Shut down pending tasks.

configure(config)

Configure the CSC.

convert_time(timestamp)

Convert string to datetime object and then convert to unix timestamp.

do_disable(data)

Transition from State.ENABLED to State.DISABLED.

do_enable(data)

Transition from State.DISABLED to State.ENABLED.

do_exitControl(data)

Transition from State.STANDBY to State.OFFLINE and quit.

do_setAuthList(data)

Update the authorization list.

do_setLogLevel(data)

Set logging level.

do_standby(data)

Transition from State.DISABLED or State.FAULT to State.STANDBY.

do_start(data)

Transition from State.STANDBY to State.DISABLED.

end_disable(data)

End do_disable; called after state changes but before command acknowledged.

end_enable(data)

End do_enable; called after state changes but before command acknowledged.

end_exitControl(data)

End do_exitControl; called after state changes but before command acknowledged.

end_standby(data)

End do_standby; called after state changes but before command acknowledged.

end_start(data)

End do_start; called after state changes but before command acknowledged.

fault(code, report[, traceback])

Enter the fault state and output the errorCode event.

get_config_pkg()

Get the name of the configuration package, e.g.

handle_summary_state()

Handle summary state transitions.

implement_simulation_mode(simulation_mode)

Implement going into or out of simulation mode.

make_from_cmd_line(index[, check_if_duplicate])

Construct a CSC from command line arguments.

put_log_level()

Output the logLevel event.

read_config_dir()

Read the config dir and put configurationsAvailable if changed.

read_config_dir_loop()

read_config_files(config_validator, ...[, ...])

Read a set of configuration files and return the validated config.

set_simulation_mode(simulation_mode)

Set the simulation mode.

start()

Finish constructing the CSC.

start_phase2()

Handle the initial state.

telemetry()

Implement telemetry loop.

Attributes Documentation

config_dir

Get or set the configuration directory.

Parameters
config_dirstr, pathlib.Path

New configuration directory.

Returns
config_dirpathlib.Path

Absolute path to the configuration directory.

Raises
ValueError

If the new configuration dir is not a directory.

default_initial_state: State = 5
disabled_or_enabled

Return True if the summary state is State.DISABLED or State.ENABLED.

This is useful in handle_summary_state to determine if you should start or stop a telemetry loop, and connect to or disconnect from an external controller

domain
enable_cmdline_state = True
simulation_help: str | None = None
simulation_mode

Get the current simulation mode.

0 means normal operation (no simulation).

Raises
ExpectedError

If the new simulation mode is not a supported value.

summary_state

Get the summary state as a State enum.

valid_simulation_modes: Sequence[int] = [0, 1, 2]
version = '?'

Methods Documentation

classmethod add_arguments(parser: ArgumentParser) None

Add arguments to the parser created by make_from_cmd_line.

Parameters
parserargparse.ArgumentParser

The argument parser.

Notes

If you override this method then you should almost certainly override add_kwargs_from_args as well.

classmethod add_kwargs_from_args(args: Namespace, kwargs: dict[str, Any]) None

Add constructor keyword arguments based on parsed arguments.

Parameters
argsargparse.Namespace

Parsed command.

kwargsdict

Keyword argument dict for the constructor. Update this based on args. The index argument will already be present if relevant.

Notes

If you override this method then you should almost certainly override add_arguments as well.

async classmethod amain(index: int | enum.IntEnum | bool | None, **kwargs: Any) None

Make a CSC from command-line arguments and run it.

Parameters
indexint, enum.IntEnum, True, or None

If the CSC is indexed, do one of the following:

  • Specify True to make index a required command-line argument that accepts any nonzero index.

  • Specify an enum.IntEnum class to make index a required command-line argument that only accepts the enum values.

  • Specify a non-zero integer to use that index. This is rare; if the CSC is indexed then the user should usually be allowed to specify the index.

If the CSC is not indexed, specify None or 0.

**kwargsdict, optional

Additional keyword arguments for your CSC’s constructor.

assert_enabled(action: str = '') None

Assert that an action that requires ENABLED state can be run.

Parameters
actionstr, optional

Action attempted. Not needed if this is called at the beginning of a do_... method, since the user will know what command was called.

async begin_disable(data: BaseMsgType) None

Begin do_disable; called before state changes.

Parameters
dataDataType

Command data

async begin_enable(data: BaseMsgType) None

Begin do_enable; called before state changes.

Parameters
dataDataType

Command data

async begin_exitControl(data: BaseMsgType) None

Begin do_exitControl; called before state changes.

Parameters
dataDataType

Command data

async begin_standby(data: BaseMsgType) None

Begin do_standby; called before the state changes.

Parameters
dataDataType

Command data

async begin_start(data: BaseMsgType) None

Begin do_start; configure the CSC before changing state.

Parameters
datacmd_start.DataType

Command data

Notes

The override field must be one of:

  • The name of a config label or config file

  • The name and version of a config file, formatted as <file_name>:<version>, where the version is a git reference, such as a git tag or commit hash. This form does not support labels.

async check_for_duplicate_heartbeat(num_messages: int = 5) int

Monitor heartbeat events and return True if any have a different private_origin.

Intended for use by check_if_duplicate.

The heartbeat loop should be running before this is called. This avoids the issue that if 2 CSCs are started at the same time then neither will see the other one’s heartbeat. This code also assumes that will be true; it will likely raise asyncio.TimeoutError if not.

Parameters
num_messagesfloat

The number of heartbeat messages to read.

Returns
originint

private_origin field of duplicate heartbeat, or 0 if none detected.

Raises
asyncio.TimeoutError

If no heartbeat seen within the specified time.

async close(exception: Exception | None = None, cancel_start: bool = True) None

Shut down, clean up resources and set done_task done.

May be called multiple times. The first call closes the Controller; subsequent calls wait until the Controller is closed.

Subclasses should override close_tasks instead of close, unless you have a good reason to do otherwise.

Parameters
exceptionException, optional

The exception that caused stopping, if any, in which case the self.done_task exception is set to this value. Specify None for a normal exit, in which case the self.done_task result is set to None.

cancel_startbool, optional

Cancel the start task? Leave this true unless calling this from the start task.

Notes

Removes the SAL log handler, calls close_tasks to stop all background tasks, pauses briefly to allow final SAL messages to be sent, then closes the dds domain.

async close_tasks() None

Shut down pending tasks. Called by close.

async configure(config)

Configure the CSC.

Parameters
configobject

The configuration, as described by the config schema, as a struct-like object.

Notes

Called when running the start command, just before changing summary state from State.STANDBY to State.DISABLED.

convert_time(timestamp)

Convert string to datetime object and then convert to unix timestamp.

This is used to convert the string that MeteoBlue returns for time into a timestamp that can be published over DDS.

Parameters
timestampstr

The time to convert.

Returns
timestamplist of int

An array of timestamps converted from the date string.

async do_disable(data: BaseMsgType) None

Transition from State.ENABLED to State.DISABLED.

Parameters
datacmd_disable.DataType

Command data

async do_enable(data: BaseMsgType) None

Transition from State.DISABLED to State.ENABLED.

Parameters
datacmd_enable.DataType

Command data

async do_exitControl(data: BaseMsgType) None

Transition from State.STANDBY to State.OFFLINE and quit.

Parameters
datacmd_exitControl.DataType

Command data

async do_setAuthList(data: BaseMsgType) None

Update the authorization list.

Parameters
datacmd_setAuthList.DataType

Authorization lists.

Notes

Add items if the data string starts with “+”, ignoring duplicates (both with respect to the existing items and within the data string). Remove items if the data string starts with “-”, ignoring missing items (items specified for removal that do not exist). Ignore whitespace after each comma and after the +/- prefix.

async do_setLogLevel(data: BaseMsgType) None

Set logging level.

Parameters
datacmd_setLogLevel.DataType

Logging level.

async do_standby(data: BaseMsgType) None

Transition from State.DISABLED or State.FAULT to State.STANDBY.

Parameters
datacmd_standby.DataType

Command data

async do_start(data: BaseMsgType) None

Transition from State.STANDBY to State.DISABLED.

Parameters
datacmd_start.DataType

Command data

async end_disable(data: BaseMsgType) None

End do_disable; called after state changes but before command acknowledged.

Parameters
dataDataType

Command data

async end_enable(data: BaseMsgType) None

End do_enable; called after state changes but before command acknowledged.

Parameters
dataDataType

Command data

async end_exitControl(data: BaseMsgType) None

End do_exitControl; called after state changes but before command acknowledged.

Parameters
dataDataType

Command data

async end_standby(data: BaseMsgType) None

End do_standby; called after state changes but before command acknowledged.

Parameters
dataDataType

Command data

async end_start(data: BaseMsgType) None

End do_start; called after state changes but before command acknowledged.

Parameters
dataDataType

Command data

async fault(code: int | None, report: str, traceback: str = '') None

Enter the fault state and output the errorCode event.

Parameters
codeint

Error code for the errorCode event. If None then errorCode is not output and you should output it yourself. Specifying None is deprecated; please always specify an integer error code.

reportstr

Description of the error.

tracebackstr, optional

Description of the traceback, if any.

static get_config_pkg()

Get the name of the configuration package, e.g. “ts_config_ocs”.

async handle_summary_state()

Handle summary state transitions.

If the CSC transitions to the disabled (or enabled) state, start the telemetry loop. If exiting out of disabled (or enabled) state, stop the telemetry loop.

async implement_simulation_mode(simulation_mode: int) None

Implement going into or out of simulation mode.

Deprecated. See simulation mode for details.

Parameters
simulation_modeint

Requested simulation mode; 0 for normal operation.

Raises
ExpectedError

If simulation_mode is not a supported value.

classmethod make_from_cmd_line(index: int | enum.IntEnum | bool | None, check_if_duplicate: bool = False, **kwargs: Any) BaseCsc

Construct a CSC from command line arguments.

Parameters
indexint, enum.IntEnum, True, or None

If the CSC is indexed, do one of the following:

  • Specify True to make index a required command-line argument that accepts any nonzero index.

  • Specify an enum.IntEnum class to make index a required command-line argument that only accepts the enum values.

  • Specify a non-zero integer to use that index. This is rare; if the CSC is indexed then the user should usually be allowed to specify the index.

If the CSC is not indexed, specify None or 0.

check_if_duplicatebool, optional

Check for heartbeat events from the same SAL name and index at startup (before starting the heartbeat loop)? The default is False, to match the BaseCsc default. Note: handled by setting the attribute directly instead of as a constructor argument, because CSCs may not all support the constructor argument.

**kwargsdict, optional

Additional keyword arguments for your CSC’s constructor.

Returns
csccls

The CSC.

Notes

To add additional command-line arguments, override add_arguments and add_kwargs_from_args.

async put_log_level() None

Output the logLevel event.

async read_config_dir() None

Read the config dir and put configurationsAvailable if changed.

Output the configurationsAvailable event (if changed), after updating the overrides and version fields. Also update the version field of evt_configurationApplied, in preparation for the next time the event is output.

async read_config_dir_loop() None
classmethod read_config_files(config_validator: Draft7Validator, config_dir: Path, files_to_read: list[str], git_hash: str = '') SimpleNamespace

Read a set of configuration files and return the validated config.

Parameters
config_validatorjsonschema validator

Schema validator for configuration.

config_dirpathlib.Path

Path to config files.

files_to_readList [str]

Names of files to read, with .yaml suffix. Empty names are ignored (a useful feature for BaseConfigTestCase). The files are read in order, with each later file overriding values that have been accumulated so far.

git_hashstr, optional

Git hash to use for the files. “” if current.

Returns
types.SimpleNamespace

The validated config as a simple namespace.

Raises
ExpectedError

If the specified configuration files cannot be found, cannot be parsed as yaml dicts, or produce an invalid configuration (one that does not match the schema).

async set_simulation_mode(simulation_mode: int) None

Set the simulation mode.

Await implement_simulation_mode, update the simulation mode property and report the new value.

Parameters
simulation_modeint

Requested simulation mode; 0 for normal operation.

async start() None

Finish constructing the CSC.

async start_phase2() None

Handle the initial state.

Called after start.

async telemetry()

Implement telemetry loop.

Download the forecast information from the Meteoblue API to memory. Clean up the data for DDS publication. Take data from json format and publish to DDS telemetry items.